Maintenance software for water and wastewater utilities
Updated
FleetZap gives water and wastewater utilities scheduled maintenance for pumps, blowers, valves and lift stations, rounds that capture readings against limits, and a full history for every asset, both at the plant and out on the collection system.
Lift stations miles from the plant
Water and wastewater utilities maintain fixed plant equipment and assets scattered across a service area. A treatment plant has pumps, blowers, clarifier drives, chemical feed systems and generators; the network adds lift stations, hydrants, valves and the vac trucks and service vehicles that look after them. Much of it runs around the clock, so preventive work follows run hours and the manufacturer’s intervals.
Lift stations and wells sit miles from the plant, crews rotate, and what anyone knows about a particular pump may live with the one operator who has looked after it for years. Rounds produce readings that get written down and filed, so a motor drawing a little more current each month goes unnoticed. When a station alarms at night, the on-call crew needs that pump’s history on the phone in their truck.
Lift station wet wells and valve vaults put a safety step into routine work. Sewage can give off hydrogen sulfide, and OSHA’s confined space standard (29 CFR 1910.146) treats a space that contains or could contain a hazardous atmosphere as permit-required. That is one reason utilities favor pumps that can be pulled on guide rails without anyone going into the well, and plan the job so the crew arrives with a gas meter and an attendant. A frequent call-out is a pump clogged with wipes and rags. If the same pump keeps tripping on high current, failure codes on each repair make the pattern visible, and you can look at what is reaching that station.
Remote stations, paper rounds and hidden standby faults
- Assets everywhere: Lift stations, wells and valves are spread across the service area, some of them a long drive from the plant.
- Readings nobody trends: Pressures, amps and temperatures go onto paper round sheets and never get compared month to month.
- Redundancy hides problems: A standby pump with a seized check valve stays hidden until the duty pump trips.
- Retirements take the history: When a long-serving operator retires, what they knew about each pump and valve often leaves with them.
Station locations, reading limits and exercise schedules
- Locations for every site: Set up each plant, lift station or zone as a location with an address and map position, nested where it helps.
- Rounds with readings: Reading steps carry a unit and min/max limits. A value outside the range fails that step and opens a repair work order.
- PM by run hours or calendar: Pump, blower and generator service runs on hours or date, whichever comes first, for one asset or a whole category.
- Field app for crews: Crews see their jobs, scan an asset label, record readings and photos; step answers and photos made in a station with no signal sync later.
- Standby equipment on schedule: Put standby pumps and generators on a recurring exercise and test procedure, and each result lands in that unit’s history.
- History that stays: Work, failure codes, parts and readings stay on each asset, so the next crew can see what was done and why.
Pumps, blowers, generators and vac trucks
- Pumps and motors
- Blowers
- Lift stations
- Standby generators
- Valves and hydrants
- Chemical feed systems
- Vac and jetter trucks
- Service trucks
Pump failures and the planned work ratio
- PM compliance: Low PM compliance at outlying lift stations often means crews skip the long drive; group those stops into one route day.
- MTBF: Falling MTBF on one pump model can point at seals or impellers; compare stations before changing the spec.
- Backlog: A backlog that swells after every storm shows how far wet-weather call-outs set planned station work back.
- Planned vs reactive: If reactive work rises, check whether standby units are failing on demand because their exercise tests lapsed.
Free tools for this
- Pipe schedule chart: OD and wall for Schedule 10, 40, 80 and 160 pipe, with ID and weight
- FEMA equipment rates 2025: FEMA’s 2025 Schedule of Equipment Rates, and the cost for your hours
- NPT pipe thread size chart: Pipe thread sizes, threads per inch, outside diameter and tap drills
- Equipment depreciation calculator: Straight-line, by the hour meter and declining balance, with book value
Sources
FleetZap Maintenance
Work orders, PM, parts, compliance, assets and KPIs. Explore FleetZap Maintenance.
Frequently asked questions
Can FleetZap track assets at many different sites?
Yes. Each site is a location with an address, coordinates and optional sub-locations, and every asset belongs to one. Lists, the map and reports filter by location, so a collection crew sees only the lift stations on its route while plant staff see the treatment plant.
Can operators record readings during rounds?
Yes. A procedure can include reading steps with a unit and min/max limits, such as discharge pressure or motor current. A value outside the range fails the step and opens a repair work order on its own, and the readings stay on the work order history for later comparison.
Does it work without cell coverage?
Partly. Inside a concrete station or vault with no signal, technicians’ step answers, comments, photos and status changes are saved on the phone and sync once it’s back online.
Is FleetZap a SCADA replacement?
No. FleetZap manages maintenance: work orders, schedules, inspections, parts and history. Process monitoring and control stay in your SCADA system. You can enter asset readings by hand, and threshold automations open work orders from the readings you record, so an operator’s round can still start a repair.