Facility maintenance: what it covers and how to run it
Updated · Reviewed by Israel Margulies, founder and CEO of High Point GPS
Facility maintenance is the work that keeps a building or plant safe, comfortable and running: servicing its equipment, repairing what breaks, and inspecting life-safety systems on a schedule. It covers the building itself (roof, doors, floors), the systems inside it (HVAC, plumbing, electrical, fire protection) and, in a plant, the production equipment as well.
What facility maintenance includes
A facilities team looks after two kinds of assets. Fixed building systems include rooftop units, boilers, chillers, water heaters, pumps, elevators, generators, lighting, sprinklers and fire alarms. Then there is the fabric of the building: roofs, gutters, doors and locks, windows, flooring, paint, parking lots and grounds. A manufacturing plant adds production lines, compressors, conveyors and forklifts, which is why searches for plant maintenance and facility maintenance overlap so much.
In a small building, one maintenance technician and a list of service contractors handle all of it. A campus or plant has a facilities manager, technicians split by trade, and contracts for elevators, fire protection and HVAC controls. Either way, the work arrives two ways: from a calendar of planned tasks and from people reporting problems.
Types of facility maintenance
Most teams mix several approaches and assign each asset the one that fits its cost and risk.
- Preventive maintenance: tasks on a fixed calendar or run-hour interval, such as filter changes, belt checks and lubrication
- Corrective maintenance: repairs after someone reports a fault, from a dripping tap to a failed pump
- Predictive or condition-based maintenance: acting on measurements such as vibration, temperature, pressure drop across a filter or oil analysis
- Run to failure: a deliberate choice for cheap, non-critical items like light bulbs in a storage room
- Inspections and testing: life-safety checks the fire code, OSHA or your insurer require, with a record of each one
- Deferred maintenance: work you know is needed but have postponed, which you should track as a list with costs
Why planned work pays off in buildings
The US Department of Energy’s Federal Energy Management Program (FEMP) publishes an Operations & Maintenance Best Practices Guide for facility managers (Release 3.0, 2010). It cites an older study in which more than 55% of maintenance resources and activities at an average facility were reactive, against 31% preventive and 12% predictive. The same guide puts the savings of a preventive program at an estimated 12% to 18% over reactive maintenance, and says O&M programs aimed at energy and water efficiency are estimated to save 5% to 20% on energy bills without major capital spending.
Those are national estimates, so check them against your own cost records before you quote them to an owner. The mechanism is easy to see in any building: a clogged filter makes the air handler work harder, a slipping belt wears out early, and a failure at 4 p.m. on a Friday means overtime and a premium for the contractor.
Life-safety items you cannot let slide
Some facility tasks carry a legal requirement, and an inspector will ask for the record. Under OSHA 29 CFR 1910.37, exit routes must be free and unobstructed, and safeguards such as sprinkler systems, alarm systems, fire doors and exit lighting must be in proper working order at all times. Exit signs must be lit to at least five foot-candles by a reliable light source, or be self-luminous signs that meet OSHA’s minimum.
For portable fire extinguishers, OSHA 1910.157 requires a visual inspection every month and an annual maintenance check. The employer records the annual maintenance date and keeps that record for one year after the last entry or the life of the shell, whichever is less. Stored-pressure dry chemical extinguishers that need a 12-year hydrostatic test must also be emptied and serviced every 6 years. Sprinklers, fire alarms, emergency generators and elevators follow NFPA codes and state or local rules, which your fire marshal or service contractor can confirm for your building.
Building maintenance checklist by frequency
Use this as a starting list and adjust it to your building’s equipment and each manufacturer’s manual. The intervals are typical practice, except the extinguisher and exit route items, which come from the OSHA rules above.
- Daily: walk the building for leaks, trip hazards, burned-out lights and blocked exit routes (OSHA requires them free and unobstructed); note boiler and chiller readings so a drift shows up before an alarm; triage new requests
- Weekly: after any heavy rain, clear roof drains and scuppers; check restroom fixtures and floor drains in the rooms that generate most complaints; look at generator fuel level and battery charger status
- Monthly: initial and date the tag on every fire extinguisher; check HVAC filter pressure drop or condition; run each eyewash station; open and release fire doors to confirm closers and panic hardware latch; exercise the emergency generator if its code or manual calls for it
- Quarterly: HVAC belt tension and bearing noise; condenser and evaporator coils, cleaned when dirty; roof membrane, seams and flashing; run water through fixtures in rarely used rooms
- Twice a year: heating and cooling changeover, gutter cleaning, a walk of parking lots and sidewalks for heaves and potholes, backflow preventer tests if your water utility schedules them
- Annually: extinguisher maintenance by a qualified service, fire alarm and sprinkler inspections by your contractor, elevator inspection, infrared scan of electrical panels, and a review of the deferred maintenance list before the budget is set
- Every 6 years: empty and service stored-pressure dry chemical extinguishers that require a 12-year hydrostatic test
Organizing the work: requests, locations and records
Two pieces of setup make every later task easier. The first is one front door for requests. When problems arrive by email, phone, radio and hallway conversation, some get lost and nobody can say how long they waited. A request form or QR code on each room, with a photo, gives you a queue you can sort by urgency.
The second is a location tree. Give every building, floor and room an entry, and attach each piece of equipment to the room it sits in. When a request comes in for Room 214, the technician sees that the room has a fan coil unit installed in 2016, what was done to it last time, and which filter it takes. Close each job with what you found and what you did, so that next year’s budget rests on records instead of memory.
One request from report to close (hypothetical)
Here is how a single complaint should move through the system, using made-up details. At 9:10 a teacher in Room 214 scans the QR label by the door and reports that the fan coil unit is rattling and the room is warm, with a short video. The facilities coordinator approves it into a work order, sets it to medium priority and assigns the HVAC technician.
The technician opens the job on a phone and sees the unit’s record: FCU-214, installed 2016, filter changed in March, takes a 16 x 20 x 1 filter. On site the filter is clogged and a blower set screw has worked loose. The technician tightens the screw, replaces the filter, logs a supply air reading after ten minutes and closes the job with problem, cause and remedy filled in and 45 minutes of labor.
Back at the desk, the coordinator sees a filter only seven months old that was already clogged, and shortens that unit’s filter interval. One request has turned into a change in the schedule, which is the point of keeping the record.
Facility maintenance in FleetZap
FleetZap is cloud maintenance software (a CMMS) that runs in a browser and on any phone. Locations nest, for example plant › building › bay, and every asset has a home location, so lists filter by building. Staff and occupants report problems through a public request link or by scanning a QR label, with up to five photos and no account; you approve a request into a work order in one click.
Preventive schedules open work orders by calendar or run hours with the procedure attached. Inspection steps can record readings with minimum and maximum limits, photos and signatures, and a failed item opens one linked repair work order. Repairs close with problem, cause and remedy codes, so repeat failures show up in a report. Contractor jobs go to an outside vendor with their reference and charge on the job, and reports show PM compliance, planned vs. reactive work, backlog and cost by asset. FleetZap started with equipment fleets; the same tools cover a building’s fixed equipment.
Key takeaways
- Build your first PM round around assets whose failure closes a room or breaks a code requirement; comfort items can wait for the second round.
- Set a target response time per request type (same day for leaks and loss of heat, for example) and report how often you meet it.
- Get each contractor inspection report attached to the asset within a week of the visit, while you can still ask the contractor about it.
- Review the run-to-failure list once a year and move any item that failed and closed a room more than once to preventive.
Free tools for this
- Duct size calculator (ductulator): Round and rectangular duct size for an airflow at a friction rate, with velocity
- Three-phase power calculator (kW, kVA, amps): kW and kVA from volts and amps, and amps from a kVA load
- Refrigerant pressure chart (R-134a, R-410A, R-22): Saturation pressure by temperature, and superheat and subcooling from a gauge reading
- MERV rating chart: What MERV 1 to 16 catches, and MERV vs FPR and MPR
Sources
FleetZap Maintenance
Work orders, PM, parts, compliance, assets and KPIs. Explore FleetZap Maintenance.
Frequently asked questions
What is the difference between facility maintenance and facility management?
Facility maintenance is the hands-on work: servicing equipment, making repairs and running inspections. Facility management is broader and includes space planning, leases, security, cleaning contracts, energy purchasing and budgets. In smaller organizations one person often does both, while large campuses have a facility manager who oversees a separate maintenance team and its contractors.
What does a building maintenance checklist include?
A building maintenance checklist groups tasks by frequency: daily walk-throughs for leaks and blocked exits, monthly fire extinguisher and filter checks, quarterly HVAC and roof inspections, and annual contractor inspections of fire alarms, sprinklers and elevators. Each item should name the asset, the task and who signs it off, so you can prove it was done.
What is plant maintenance?
Plant maintenance is facility maintenance for a manufacturing or processing site. Along with the building systems, it covers production equipment such as conveyors, compressors, pumps, packaging lines and forklifts. Because downtime stops output, plants lean more on preventive and condition-based maintenance, spare parts on the shelf, and lockout/tagout procedures for servicing machines.
How often should a facility do preventive maintenance?
It depends on the asset. Follow each manufacturer’s manual for equipment intervals, which may be calendar based or by run hours. Life-safety systems follow their rules, such as OSHA’s monthly visual inspection and annual maintenance for portable fire extinguishers. Many teams set HVAC filter checks monthly and coil and belt work quarterly, then adjust from their own failure history.
What skills does a facility maintenance technician need?
A facility maintenance technician needs working knowledge of HVAC, plumbing, electrical and general carpentry, plus the ability to read equipment manuals and wiring diagrams. Anyone who services equipment that could release ozone-depleting refrigerant needs EPA Section 608 technician certification, and some states license trades on top. Good record keeping matters too, since inspections and repairs need dated entries an auditor can follow.