BTU and AC tonnage calculator
The cooling capacity a room needs in BTU per hour, using ENERGY STAR’s sizing table and adjustments, with the tons of cooling and the airflow in CFM.
Your numbers
The roomAirflow See your resultResult
Cooling needed 12,000 BTU per hour12,000 BTU from the table, then the adjustments Tons of cooling 1.00 tons1 ton = 12,000 BTU per hour Airflow 556 CFMsensible heat at a 20°F drop; the 400 CFM per ton rule gives 400 Stop working this out by handFleetZap tracks every AC unit as an asset with its tonnage and filter size, and PM schedules open its services on the calendar.
See FleetZap Maintenance · Try the demoThe formula
Tons = BTU per hour ÷ 12,000 · CFM = BTU per hour ÷ (1.08 × Temperature drop)
The table and the adjustments are ENERGY STAR’s for room air conditioners: −10% for a heavily shaded room, +10% for a very sunny one, +600 BTU for each person beyond two, and +4,000 BTU for a kitchen. With the example: 500 sq ft takes 12,000 BTU per hour, or 1 ton. 1.08 is the sensible heat factor for standard air. This is a quick estimate for a room: sizing a central system or a building properly takes a load calculation (ACCA Manual J), which accounts for insulation, windows, climate and ductwork. Table from ENERGY STAR.
Using the numberWhat to do with it
- Oversized units short-cycle and leave the room damp; bigger isn’t better.
- Clean coils and change filters on a schedule, so the unit delivers its rated capacity.
- Track every AC unit as an asset with its tonnage, refrigerant and filter size.
ENERGY STAR room AC sizing chart
| Area to cool (sq ft) | Capacity needed (BTU per hour) |
|---|---|
| 100 up to 150 | 5,000 |
| 150 up to 250 | 6,000 |
| 250 up to 300 | 7,000 |
| 300 up to 350 | 8,000 |
| 350 up to 400 | 9,000 |
| 400 up to 450 | 10,000 |
| 450 up to 550 | 12,000 |
| 550 up to 700 | 14,000 |
| 700 up to 1,000 | 18,000 |
| 1,000 up to 1,200 | 21,000 |
| 1,200 up to 1,400 | 23,000 |
| 1,400 up to 1,500 | 24,000 |
| 1,500 up to 2,000 | 30,000 |
| 2,000 up to 2,500 | 34,000 |
Free chart from fleetzap.com/tools/btu-calculator
Guides behind this calculator
HVAC contractors Facility maintenance software Rooftop HVAC unit maintenanceMore in Shop & field
Hydraulic cylinder calculator Bolt torque calculator Air compressor CFM calculator Sling angle calculator Generator size calculator Generator fuel consumption calculator Fuel tank capacity calculator 2-stroke fuel mix calculator Bearing size chart (6000, 6200, 6300) Hydraulic hose size chart and velocity calculator Welding cable size chart Grease compatibility chart Belt length and pulley calculator Hydraulic horsepower calculator Forklift capacity calculator Steel weight calculator Feeds and speeds calculator (SFM, RPM, feed rate) Three-phase power calculator (kW, kVA, amps) Weight per gallon calculator Duct size calculator (ductulator) Horsepower to torque calculator All free toolsEmbed this calculator
Put this btu and ac tonnage calculator on your own site, free: paste the code into any page. It stays up to date, and there’s nothing to install.
FleetZap Maintenance
The heart of FleetZap, and everything a maintenance team needs in one place: work orders and preventive maintenance, inspections and the field app, plus a parts store with purchasing, compliance and certificate tracking, multi-location assets with a full lifecycle, and the KPIs that prove it’s working.
- Work orders
- Preventive maintenance
- Procedures, inspections & field app
- Parts & purchasing
- Compliance
- Assets, reports & KPIs
Good to know
How many BTU do I need per square foot?It isn’t a flat number per square foot. ENERGY STAR’s table gives 5,000 BTU per hour for 100 to 150 sq ft, 12,000 for 450 to 550 sq ft and 24,000 for 1,400 to 1,500 sq ft, then adjusts for sun, people and kitchens.
How many BTU is a ton?12,000 BTU per hour.
Can I size central air with this?Only as a rough check. A central system or building needs a load calculation (ACCA Manual J).
How many BTU are in a ton of cooling?One ton of cooling is 12,000 BTU per hour. Divide the BTU the calculator gives by 12,000 to get the tonnage of the AC unit.
See FleetZap on your own fleet
Book a 20-minute walkthrough, or poke around the live demo company right now.
- Set up with you, on your machines
- Works fully by hand, GPS optional
- Live demo, no sign-up